Tomzn Tovpd160ec Manual - Better

: Ensure the input and output are connected strictly according to the product markings. Neutral line ( N ) must be connected reliably for the protector to function.

To enter setup, press the . Use the UP and DOWN buttons to change values. The device cycles through these key parameters: Description Default Value Adjustable Range A1 Power-on delay (Wait time before connecting load) 1s – 500s A2 Over-voltage protection threshold 230V – 300V (or OFF) A3 Over-voltage recovery voltage 225V – 295V A4 Over-voltage recovery delay time 1s – 500s A5 Over-voltage action time (Trip speed) 0.1s – 30s A6 Under-voltage protection threshold 140V – 210V (or OFF) A7 Under-voltage recovery voltage 145V – 215V A8 Under-voltage recovery delay time 1s – 500s A9 Under-voltage action time 0.1s – 30s A10 Over-current protection threshold 1A – 63A A11 Over-current recovery delay time 1s – 500s A12 Over-current action time 0.1s – 30s A13 Voltage calibration (Fine-tune display accuracy) Critical Installation Tips tomzn tovpd160ec manual better

To disable over-voltage protection, press the UP button until it reaches . : Ensure the input and output are connected