Fanuc 10m Parameter Manual __exclusive__ -

Because this is a 40-year-old controller, distribution rights have relaxed, but copyright still exists.

To enable program transfers via RS-232, configure the following "Service Page" and standard parameters: Parameter Recommended Value Description xxx01000 ISO Mode enabled. #0020 2 I/O Channel select (Foreground). #5001 1 Device Select. #5110 3 or 4 Device Type (typically 3 for DC Codes/Xon-Xoff). #5111 1 or 2 Stop Bits (1 or 2 to match PC software). #5112 10 or 11 Baud Rate (10=4800, 11=9600). 3. Machine Accuracy & Compensation Fanuc 10m Parameter Manual

function key (on some units, you may need to press it twice or use the soft keys). Find parameter (bit 0 is the PWE bit). Change the value to . The CNC will trigger a (Parameter Write Enable) alarm, which is normal. Accessing Service Parameters: Once PWE is enabled, press the soft key followed by the soft key to view and edit the main parameter list. 2. Essential RS-232 Communication Parameters #5001 1 Device Select